。Bistable power relay, very low power consumption, temporarily overloadable up to 60 A, temporarily overloadable up to 60 A. 。Separate sensor cable and switching thresholds with hysteresis and timer functions for interference-free function. 。Automatic reset once the battery voltage is back in normal range (charge). 。No self-consumption when switched off via external switch, can also be remotely operated by external switch. Important product features: 。Switching current 40 A, less than 3 mA (according to EN 13976). "Motor" design with higher shut-off thresholds the starting ability in emergency vehicles with only one battery circuit according to DIN EN 1789. Solid screw terminals for battery and load cable cross-sections up to 10 mm² - Operating voltage 12 V - Switching threshold under voltage: 11.8 V - Reset point: 12.8 V - Overvoltage OFF/ON: 15.5 V / 15.0 V 。Emergency on function via switch on the device, e.g. switching status display visible from the outside. Switching status display visible from the outside - Emergency on function via switch on the device. VOTRONIC 3073 Battery Protector 40 Motor 40 A 12 V Battery Guard Surge Protection.VOTRONIC 3073 Battery Protector 40 Motor 40 A 12 V Battery Guard Surge Protection. we make online shopping easy VOTRONIC 3073 Battery Protector 40 Motor 40 A 12 V Battery Guard Surge Protection, Trend frontier Discover and Shop the Latest in Fashion.
Solar battery guard upgrade#
Promotional discounts VOTRONIC 3073 Battery Protector 40 Motor 40 A 12 V Battery Guard Surge Protection: Car & Motorbike, Upgrade your shopping experience. VOTRONIC 3073 Battery Protector 40 Motor 40 A 12 V Battery Guard Surge Protection Deep Cycle Batteries & Accessories .uk, With our 100% satisfaction guarantee.
In our testing process, some of the inverters resumed power, and some did not.
Solar battery guard manual#
There are too many inverters to test in house, so we suggest you follow the next step to determine if your inverter requires a manual reset. flipping the power switch back on if power is removed from the DC input. Keep in mind that some power inverters need to be manually reset i.e. The LVS will prevent deep discharges of your battery bank that shorten the life of your batteries. Once your batteries recharge to a safer level, the LVS will restore DC power to the inverter's DC inputs.
When the relay disconnects, the inverter will shut down and prevent further draw on the battery or batteries. The low voltage relay will automatically disconnect the DC power between the batteries and inverter, and/or other DC devices like lights or water heating elements. What does the Low Voltage Shutdown (LVS) do? Simply cut the positive line to your DC device and wire it back together through the relay quick connect lugs.
*Now comes with quick connect lugs accepting 2 to 8 guage wire. The side posts are capable of 150 amps of continuous power. You can use the Battery Guard with the battery disconnect function and auxillary side post function simultaneously, just battery disconnect, or just the auxillary side posts. There are many additional possibilities for the auxillary side posts.
The normally open auxillary side posts of the relay can be used to route a backup charging source to the battery, connect an auxillary battery, and/or activating an alarm when the battery is low. Prolong the lifespan of your expensive lead acid or lithium batteries with this simple device - completely preset to detect battery voltage. Use our Low Voltage Battery Protection Relay Switch to temporarily disconnect your power inverter or other DC devices from your batteries. 100 Amp Automatic Low Voltage Shutdown Relay Switchįor Lithium, Lead Acid and Sealed AGM Batteries Automatic Battery Disconnect Switch Protect your batteries from being over-discharged